- Accuracy Class1.0 IEC 61036/CBIP88
- Accurate on Distorted waveforms
- Simultaneous sampling of Volts & Amps
- Low PT, CT burden
- Crisp, Bright Display
- View 3 parameters together
- Auto scaling from Kilo to Mega to Giga
- Programmable CT, PT ratios
- Built-in phase analyser
- Quick and easy installation
- Auto scrolling
- Communication with PCs, PLCs, DCS through optional RS 485 Serial Port
- 10 year back-up of integrated data
- Tamper proof cover option
- Sealed dust-proof construction
- Bench top version available
- Simplest to operate-One touch FAV key
- It measures 4 Quadrant Power & 2 Quadrant Energy
Applications
- Control Panels
- Motor Control Centers
- Power Distribution Panels
- Connection to Plant Monitoring & Control Systems
- Genset Panels
- Original Equipment Manufacturers (OEMs)
User Programmable
- Delta 3E or Star 3E
- PT, CT Ratios Primary & Secondary
Rugged Construction
Confirms to:
- Emission: CISPR22
- Fast Transient: Up to 2kV
IEC 61000 - 4 - 4, level 3
- ESD : IEC61000-4-2
- Impulse voltage: 6kV, IEC60060, 1.2/50
| at a glance: |
EM6434 |
EM6400 |
| Measures : |
|
|
| Volts LN per phase & Avg. |
- |

|
| Volts LL per phase & Avg. |
- |

|
| Amps per phase & Avg. |
- |

|
| kVA per phase & total and kVAh total |
 |

|
kVAR per phase & total and kVARh total
Inductive & total Capacitive |
 |

|
| KW per phase & total and kWh total |
 |

|
| PF per phase & 3 phase |
 |

|
| Frequency |
- |

|
| Amps Phase Angle (A) per phase |
- |

|
| Hours Run |
- |

|
| On hours |
- |

|
| Number of Outages (Interruptions) |
- |

|
|
Technical Specifications
| Sensing/Measurement |
True RMS, 1sec up date time
4 Quadrant Power & 2 Quadrant Energy |
| Input voltage |
4 Voltage inputs (V1, V2, V3, VN)
110 or 415VL-L nominal
(Range 80 to 500VL-L) |
AuxSupply
(Control Panel) |
80-270VAC, 45-65Hz
100-270VDC |
| Input current |
Current inputs (A1, A2, A3)
50mA-6A (Field configurable 1A or 5A)
Overload
10Amax Continuous
50Amax for 3 seconds |
| Burden |
0.2VAmax per Volts/Amps input
3VAmax on Auxiliary Supply |
| Frequency |
45-65Hz |
| Resolution |
RMS4 digit, Integ 8 degit |
| Digital Communications |
RS485 serial channel connection
Industry standard Modbus RTU protocol. |
| Isolation |
2000 volts AC isolation for 1 minute between communication and other circuits |
| Environmental |
Operating Temperature -10°C to +60°C (14°Fto140°F)
Storage Temperature -25°C to +70°C (-13°Fto158°F)
Humidity 5% to 95% noncondensing. |
| Weight |
400gms approx. Unpacked
500gms approx. Shipping |
Accuracy
| Measurement |
Accuracy % Reading |
Volts LN per phase
Volts LL per phase
Volts LN Avg
Volts LL Avg
|
0.5
0.5
0.5
0.5 |
Amps per phase
Amps Avg
Amps phase angle per phase
|
0.5
0.5
1° |
| Frequency |
0.1 |
Real Power per phase & total
Reactive Power per phase & total
Apparent Power per phase & total
Power Factor per phase & average
|
1.0
2.0
1.0
1.0
|
Active Energy Import
Reactive Energy (Inductive/Capacitive)
Apparent Energy
|
1.0
2.0
1.0 |
| Note: Additional error of 0.05% of full scale, for meter input current below 200mA |
|
- Brilliant 3 line, 4 digit per line,(digit height 14mm) LED display with auto-scaling capability for Kilo, Mega, Giga
- Meter can display Volts, Amps and Frequency simultaneously
- Easy set up through Front Panel keys
- Password protection for setup parameters
| |
Display pages |
EM6434 |
EM6400 |
| RMS |
VLL, A avg., F |
- |
 |
| VLN, A avg., F |
- |

|
| kVA, kW, kVAR |
 |

|
| kVA, kW, PF |

|

|
| Individual phases of the above parameters |

|

|
|
| INTEG |
kVAh |

|

|
| kWh |

|

|
| kVARh Inductive |

|

|
| kVARh Capacitive |
 |

|
| Run hours |
 |

|
| On hours |
 |

|
| Interruptions (Outages) |
- |

|
|
| |
Note: VA function selectable 3 Dorarithmatic |
|
Digital Communication
RS485 standard, communication capability using open Modbus RTU protocol. The meters can be daisy-chained using RS485 twisted pair. The baud rate can be adjusted from 1200 bps to 19,200bps.
RS485 Single Point Communication (Modbus)
RS485 Multi-Point Communication (Modbus)

| Order Infomation |
| SI |
Specify |
Option |
| 1 |
ModelNumber |
EM6400/EM6434 |
| 2 |
Accuracy |
Class1/Class0.5 |
| 3 |
Communication*
(Modbus RTU protocol) |
With/With Out RS 485 |
|
* Bulit in for EM6434
Dimension
| Bezel |
: |
96 x 96 mm |
| Depth |
: |
80 mm behind Bezel |
| Panel cutout |
: |
90(+1 -0) x 90(+1 -0) mm |
Accessories
- Optional F used Voltage Probes & Clamp-on Current Probes for portable use
- Tamper proof cover
- Safety Cover
- Connector Kit